Overview

Resolving EMC failure caused by high-speed signal coupling and unintended radiation.


Technologies

EMC | Signal integrity | High-speed electronics | Compliance engineering


Define the Problem

A product failed formal EMC testing due to radiated emissions associated with a high-speed display interface operating at 148.5 MHz.


Diagnose the Root Cause

Investigation identified signal coupling into cable structures and enclosure features, creating unintended radiating elements.


Key engineering challenges included:

  • High-speed clock frequencies

  • Cable coupling effects

  • Enclosure interactions

  • Compliance requirements


Deliver the Solution

We redesigned routing, grounding and filtering strategies to control current return paths and reduce emissions.


Key Outcomes

  • Passed EN55032 Class B with margin

  • Eliminated radiated emissions issue

  • Avoided redesign of core electronics

  • Accelerated route to compliance

 
 
 